External roof

Description

WALLTITE can be applied to the external surfaces of corrugated and profiled roof cladding. The in-situ application overcomes problem areas such as cracked roofing sheets and glazing, perished fixing bolt seals and gaps in the sheeting.

This practiclal way of insulating and weatherproofing a commercial building roof, provides a lightweight solution to condensation problems without disruption to production within the premises.

In these situations the WALLTITE needs to be provided with UV protection via a recommended membrane coating.

  • Simple, seamless insulation of critical areas
  • Suitable for virtually all substrate
  • Economic due to "fast track" installation
  • Lightweight
  • Adapts to any profile without gaps
  • High compressive strength for occasional foot traffic

Certification

WALLTITE has undergone various performance tests. Certificates are available on request.

Page functions

Print

General information:

Disclaimer

Data security

Copyright 2010

External roof

Technical data

Specification:

External roof

Internal surface emissivity:

High

External surface emissivity:

High

U-value calculation

Construction details
(external roof)

Thickness (mm)

Outside surface resistance

UV protective membrane

WALLTITE

35

Fibre cement sheeting (BS 5250)

10

Inside surface resistance

U-value

0.71W/m²K

(Correction for mechanical fasteners, Delta Uf = 0.000W/m²K)
(Correction for air gaps, Delta Ug = 0.000W/m²K)