New timber frame wall

Description

WALLTITE is applied directly between the studs onto the OSB. The stud is sufficient to meet the recommended elemental U-value.

Unwanted air leakage and air infiltration is minimised and sound attenuation improved.

Polyurethane foams are hypo allergenic and so contain no fibres or dust and no noxious vapours. Mechanical and electrical services can be fixed between the foam and the plasterboard. WALLTITE is very quick to install minimising on overhead costs, site storage and waste.

Certification

BBA Certificate No. 11/4816.

WALLTITE has undergone various performance tests.
Certificates are available on request.

BBALogo4816

Link

 

nbspluslogo

Link

Page functions

Print

General information:

Disclaimer

Data security

Copyright 2010

New timber frame wall

Technical data

Specification:

WALLTITE sprayed between studwork of timber framed wall

NBS clause:

P10 205A

Conforms to:

Part L1A 2010, Appendix A

Average depth:

92mm

U-value:

0.30W/m²K

Condensation risk:

Zero

U-value calculation

Construction details
(Timber framed wall)

Thickness (mm)

Brick – outer Leaf

103

Airspace in cavity wall construction

OSB

9

Spray applied WALLTITE

92

Cavity >= 25mm, wall

Plasterboard

12.5

Finishing plaster

2

U-value

0.30W/m²K